Related Experiment Video
Updated: Nov 19, 2025

Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
Published on: February 13, 2021
Heartech® left ventricular partitioning device improves left ventricular systolic function of patients with chronic
Xiuxiu Su1, Wenbo Yang1, Zhengbin Zhu1
1Department of Vascular and Cardiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Insights
The Heartech® left ventricular (LV) partitioning device (LVPD) shows sustained safety and efficacy in heart failure patients one year post-implantation. Echocardiographic outcomes reveal significant improvements in LV systolic function without deterioration in diastolic or right ventricular function.
Area of Science:
- Cardiology
- Medical Devices
- Heart Failure Research
Background:
- The Heartech® left ventricular (LV) partitioning device (LVPD) demonstrated initial safety and efficacy in a first-in-man study for chronic heart failure (HF) patients post-myocardial infarction (MI) at one month.
- This study extends the follow-up to one year to assess long-term echocardiographic outcomes in these patients.
Purpose of the Study:
- To evaluate the 1-year echocardiographic outcomes in patients treated with the Heartech® LVPD for heart failure post-myocardial infarction.
- To assess the device's impact on left ventricular (LV) systolic and diastolic function, and right ventricular function over a 1-year period.
Main Methods:
- Fifteen patients with HF post-MI received the Heartech® LVPD via percutaneous ventricular restoration.
- Echocardiographic parameters, including LV systolic and diastolic function, speckle-tracking analysis, and right ventricular function, were measured pre-implantation, at 1 month, and at 1 year post-implantation.
Main Results:
- Significant improvement in LV ejection fraction (42.5% to 32.47%; p=0.001) was observed at 1 year compared to pre-procedure.
- Significant reduction in LV end-diastolic volume index (106.29 to 83.30; p=0.005) and end-systolic volume index (72.47 to 50.00; p=0.001) was noted.
- No deterioration in LV diastolic function, specific strain parameters, or right ventricular function was observed at 1 year.
Conclusions:
- The Heartech® LVPD provides sustained benefits for patients with heart failure post-myocardial infarction at the 1-year follow-up.
- The device significantly improves left ventricular systolic function without compromising diastolic or right ventricular function, confirming its long-term efficacy.
Objectives:
This study presents 1-year follow-up data of echocardiographic outcomes in patients who received the Heartech® left ventricular (LV) partitioning device (LVPD) (Xinrui Medical Equipment Co. Ltd., Shanghai, China).
Background:
Our first-in-man study of the Heartech® LVPD confirmed its safety and efficacy in patients with chronic heart failure (HF) post-myocardial infarction (MI) 1 month post-implantation. This subsequent study reports the echocardiographic outcomes of these patients at 1 year of follow-up.
Methods:
Fifteen patients with HF post-MI from three cardiac intervention centers in China were successfully implanted with the Heartech® LVPD via percutaneous ventricular restoration procedures. Echocardiographic parameters-including LV systolic function, diastolic function, two-dimensional speckle-tracking analysis, and right ventricular systolic function-were obtained before device implantation and at 1 month and 1 year postoperatively.
Results:
There was no deterioration of LV diastolic function, specific strain parameters, or right ventricular function at 1 year. Relative to the echocardiographic parameters recorded before the procedure, the LV ejection fraction (32.47 ± 6.98% vs. 42.5 ± 7.41%; p = .001) was significantly improved at 1 year, while the LV end-diastolic volume index (106.29 ± 28.01 vs. 83.30 ± 31.71; p = .005) and end-systolic volume index were significantly reduced (72.47 ± 22.77 vs. 50.00 ± 19.70; p = .001).
Conclusions:
One-year echocardiographic follow-up results confirmed that no deterioration of LV diastolic function or specific strain parameters was observed and LV systolic function was significantly improved in patients with HF post-MI who were implanted with the Heartech® LVPD.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs