Related Experiment Video
Updated: Nov 19, 2025

High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Algorithm for cavo-tricuspid isthmus flutter on surface ECGs: the ACTIONS study
Daniel R Frisch1, Eitan Frankel2, Deanna Gill3
1Cardiology, Thomas Jefferson University, Philadelphia, Pennsylvania, USA.
Objective:
Cavo-tricuspid isthmus atrial flutter (CTI-AFL) is an important arrhythmia to recognise because there is a highly effective and relatively low-risk ablation strategy. However, clinical experience has demonstrated that providers often have difficulty distinguishing AFL from atrial fibrillation.
Methods:
We developed a novel ECG-based three-step algorithm to identify CTI-AFL based on established CTI flutter characteristics and verified on consecutive ablation cases of typical flutter, atypical flutter and atrial fibrillation. The algorithm assesses V1/inferior lead F-wave concordance, consistency of P-wave morphology and the presence of isoelectric intervals in the inferior leads. In this observation study, the algorithm was validated on a cohort of 50 second-year medical students. Students were paired in a control and experimental group, and each pair received 10 randomly selected ECGs (from a pool of 50 intracardiac electrogram-proven CTI-AFL and 50 AF or atypical AFL cases). The experimental group received a cover sheet with the CTI algorithm, and the control group received no additional guidance.
Results:
There was a statistically significant difference in the mean number of correctly identified ECGs among the students in the experimental and control groups (8.12 vs 5.68, p<0.001). Students who used the algorithm correctly identified 2.44 more ECGs as being CTI-AFL or not CTI-AFL. Using the electrophysiology study as the gold standard, the algorithm had an accuracy of 81%, sensitivity of 81%, specificity of 82%, positive predictive value of 78% and negative predictive value of 84% in identifying CTI-AFL.
Conclusion:
We developed a three-step ECG algorithm that provides a simple, sensitive, specific and accurate tool to identify CTI-AFL.
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
ECG Interpretation of Arrhythmias I: Sinus Arrhythmias
Types of Arrhythmias
Sinus Node Arrhythmias
Sinus Bradycardia: Originating from the sinoatrial (SA) node, sinus bradycardia involves slower impulses, resulting in a heart rate of less than 60 beats per minute (bpm). Causes include sleep, vagal stimulation, beta-blockers, hypothyroidism,...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....