Related Experiment Video
Updated: Nov 19, 2025

Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
A systematic review of digital removable partial dentures. Part I: Clinical evidence, digital impression, and
Kenji Fueki1, Yuka Inamochi1, Junichiro Wada1
1Department of Removable Partial Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University (TMDU), Tokyo, Japan.
Purpose:
This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports.
Study Selection:
We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis. We report evidence from clinical papers and case reports, digital impression-taking methods, and maxillomandibular relationship (MMR) records.
Results:
A case report electronically published in 2019 introduced a clasp-retained RPD fabricated via a full-digital workflow without a gypsum definitive cast. Computer-aided design and computer-aided manufacturing of double-crown-retained RPDs with nonmetal materials were described in some case reports. Intraoral scanners were used to obtain digital impressions and MMR records in the fabrication of digital RPDs, which have potential advantages for reducing the number of clinical appointments and simplifying laboratory procedures. Evidence from clinical trials is scarce; a randomized controlled trial reported higher patient satisfaction with digital clasp-retained RPDs than with conventional RPDs.
Conclusions:
Full-digital RPDs can be fabricated without a gypsum definitive cast. However, the indication for full-digital RPDs is limited to cases with Kennedy Class III/IV partially edentulous arches with several missing teeth. Challenges in digital impression-taking and MMR recording remain to be solved to extend these indications. More evidence from clinical trials is required to evaluate the efficacy and usefulness of digital RPDs.
More Related Videos
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021