Abstract:
In this study, Raman spectroscopy has been utilized to characterize buffalo, cow and goat fat samples by using laser wavelengths at 532 and 785 nm as excitation sources. It has been observed that Raman spectra of cow fats contain beta-carotene at 1006, 1156 and 1520 cm-1, which are absent in buffalo and goat fats. The Raman bands at 1060, 1080, 1127 and 1440 cm-1 represent the saturated fatty acids, and their concentration is found relatively higher in buffalo fats than cow and goat. Similarly, the Raman band at 1650 cm-1 represent conjugated linoleic acid (CLA) which shows its relatively higher concentration in goat fats than cow and buffalo. The Raman band at 1267 cm-1 represent unsaturated fatty acids, which shows its relatively higher concentration in goat fats than cow and buffalo. The Raman bands at 838, 870 and 1060 cm-1 depict relatively higher concentration of vitamin D in buffalo fats than cow and goat. Principal component analysis has been applied to highlight the differences among three fat types which based upon the concentration of fatty acids, CLA and vitamin D.
More Related Videos
09:32Resolving Water, Proteins, and Lipids from In Vivo Confocal Raman Spectra of Stratum Corneum through a Chemometric Approach
Published on: September 26, 2019
08:54NMR Spectroscopy as a Robust Tool for the Rapid Evaluation of the Lipid Profile of Fish Oil Supplements
Published on: May 1, 2017
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Spectroscopy of Carboxylic Acid Derivatives
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
NMR and Mass Spectroscopy of Carboxylic Acids
While α protons of carboxylic acids absorb at 2–2.5 ppm, β protons absorb further upfield.
Carboxylic acids are easily identified by dissolving them in deuterium oxide, which results in a rapid exchange of the acidic protons with deuterium. This leads to the...