Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Coherent Point Drift Peak Alignment Algorithms Using Distance and Similarity Measures for Two-Dimensional Gas
Zeyu Li1, Seongho Kim2,3, Sikai Zhong1
1Department of Computer Sciences, Wayne State University, Detroit, MI 48202.
Abstract:
The peak alignment is a vital preprocessing step before downstream analysis, such as biomarker discovery and pathway analysis, for two-dimensional gas chromatography mass spectrometry (2DGCMS)-based metabolomics data. Due to uncontrollable experimental conditions, e.g., the differences in temperature or pressure, matrix effects on samples, and stationary phase degradation, a shift of retention times among samples inevitably occurs during 2DGCMS experiments, making it difficult to align peaks. Various peak alignment algorithms have been developed to correct retention time shifts for homogeneous, heterogeneous or both type of mass spectrometry data. However, almost all existing algorithms have been focused on a local alignment and are suffering from low accuracy especially when aligning dense biological data with many peaks. We have developed four global peak alignment (GPA) algorithms using coherent point drift (CPD) point matching algorithms: retention time-based CPD-GPA (RT), prior CPD-GPA (P), mixture CPD-GPA (M), and prior mixture CPD-GPA (P+M). The method RT performs the peak alignment based only on the retention time distance, while the methods P, M, and P+M carry out the peak alignment using both the retention time distance and mass spectral similarity. The method P incorporates the mass spectral similarity through prior information and the methods M and P+M use the mixture distance measure. Four developed algorithms are applied to homogeneous and heterogeneous spiked-in data as well as two real biological data and compared with three existing algorithms, mSPA, SWPA, and BiPACE-2D. The results show that our CPD-GPA algorithms perform better than all existing algorithms in terms of F1 score.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...