Related Experiment Video
Updated: Nov 19, 2025

An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
The Circular Stapled Esophagogastric Anastomosis in Esophagectomy: No Differences in Anastomotic Insufficiency and
E Tagkalos1, P C van der Sluis1, E Uzun1
1Department of General, Visceral and Transplant Surgery, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany.
Background:
For patients undergoing an Ivor Lewis esophagectomy with a circular stapled anastomosis, the optimal diameter of the used circular stapler to restore continuity is unknown. The aim of this study was to compare the 25 mm stapled versus the 28 mm stapled esophagogastric anastomosis after Ivor Lewis esophagectomy, focusing on anastomotic insufficiency and postoperative anastomotic strictures.
Methods:
Between February 2008 and June 2019, 349 consecutive patients underwent Ivor Lewis esophagectomy with gastric conduit reconstruction and circular stapled anastomosis. Patient characteristics and postoperative results, such as anastomotic insufficiency rates, postoperative anastomotic stricture rates, time to anastomotic stricture rate, and the number of dilatations, were recorded in a prospective database and analyzed.
Results:
In 222 patients (64%), the 25 mm circular stapler was used and in 127 patients (36%) the 28 mm circular stapler was used. There were no differences in baseline characteristics. Anastomotic insufficiency rates were comparable between the 25 mm (12%) and the 28 mm groups (11%) (p = 0.751). There were no differences between postoperative anastomotic strictures in the 25 mm (14%) and the 28 mm groups (14%) (p = 0.863). Within patients with postoperative anastomotic strictures, a median number of 2 dilatations were observed in each group (p = 0.573) without differences in the time to first diagnosis (p = 0.412).
Conclusion:
There were no differences in anastomotic insufficiency and postoperative anastomotic stricture rates between the 25 mm and the 28 mm circular stapled esophagogastric anastomosis after Ivor Lewis esophagectomy. Both the 25 mm and 28 mm stapler can be safely used to create a circular stapled esophagogastric anastomosis to restore continuity after esophagectomy.
More Related Videos
Related Concept Videos
Esophageal Strictures-I: Introduction
Etiology
The primary cause of esophageal strictures is long-standing gastroesophageal reflux disease (GERD), accounting for about 70 to 80% of adult cases. Chronic acid reflux can lead to injury and scarring of the esophageal lining, culminating in...
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...

