Background:

  • Accurate risk stratification for coronary artery disease (CAD) necessitates both morphological and physiological assessment.
  • Current imaging techniques may involve significant radiation doses, posing a challenge for frequent patient monitoring.

Purpose of the Study:

  • To evaluate a novel low-dose cardiac CT technique for combined morphological and physiological assessment of CAD.
  • To determine the accuracy and radiation dose of this low-dose approach compared to a reference method.

Main Methods:

  • A low-dose cardiac CT protocol was developed, acquiring four volume scans (two rest, two stress) to measure coronary flow reserve (CFR).
  • The technique was tested in twelve swine, three with induced coronary stenosis.
  • Measurements were compared against a validated reference technique using 20 volume scans.

Main Results:

  • The low-dose technique demonstrated strong correlation with the reference method (r=0.94) for perfusion measurements.
  • Calculated perfusion values using the low-dose method were PLOW = 1.04 PREF - 0.08 mL/min/g.
  • The technique yielded a volumetric CT dose index of 8.05 mGy and SSDE of 12.80 mGy, corresponding to effective doses of 1.8 and 2.87 mSv.

Conclusions:

  • Combined morphological and physiological assessment of CAD is feasible with the evaluated low-dose cardiac CT technique.