Related Experiment Video
Updated: Nov 19, 2025

Near-Infrared Temperature Measurement Technique for Water Surrounding an Induction-heated Small Magnetic Sphere
Published on: April 30, 2018
Visualization of microwave near-field distribution in sodium chloride and glucose aqueous solutions by a
Zhirayr Baghdasaryan1,2, Arsen Babajanyan2, Levon Odabashyan2
1Department of Physics, Sogang University, Seoul, 121-742, Korea.
Abstract:
In this study, a new optical method is presented to determine the concentrations of NaCl and glucose aqueous solutions by using a thermo-elastic optical indicator microscope. By measuring the microwave near-field distribution intensity, concentration changes of NaCl and glucose aqueous solutions were detected in the 0-100 mg/ml range, when exposed to microwave irradiation at 12 GHz frequency. Microwave near-field distribution intensity decreased as the NaCl or glucose concentration increased due to the changes of the absorption properties of aqueous solution. This method provides a novel approach for monitoring NaCl and glucose in biological liquids by using a CCD sensor capable of visualizing NaCl and glucose concentrations without scanning.

