Related Experiment Video
Updated: Nov 19, 2025

A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
Minimally Invasive Reduction of Intraarticular Calcaneal Fractures With Percutaneous Fixation Using Cannulated Screws
Ahmed Shams1, Osama Gamal1, Mohamed Kamal Mesregah1,2
1Department of Orthopaedic Surgery, Faculty of Medicine, Menoufia University, Shebin El-Kom, Menoufia, Egypt.
Background:
Several minimally invasive techniques were developed for management of intraarticular calcaneal fractures. This study aimed to compare the functional and radiological outcomes of 2 minimally invasive reduction and fixation techniques using cannulated screws or Kirschner wires (K-wires) for fixation.
Methods:
This study was a retrospective comparative review of patients with displaced intraarticular calcaneal fractures, who were treated with cannulated screws or K-wires techniques. Clinical and radiological data were collected and compared between both groups. Functional outcomes and patient satisfaction using the Maryland Foot Score (MFS) and the visual analogue scale (VAS) of pain, in addition to the complications, were compared between both groups.
Results:
In total, 70 patients were included in the study: 34 in the cannulated screws group, with a mean age of 35.2 ± 4 years, and 36 in the K-wires groups, with a mean age of 33.4 ± 3 years. The operative time was shorter in the K-wires group (40.5 ± 5.6 minutes) compared to the cannulated screw group (49.5 ± 4.5 minutes), P < .001. There were no statistically significant differences between both groups regarding the radiological parameters, including Bohler's angle, angle of Gissane, calcaneal width, height, or length. The mean MFS, mean VAS, and complications were not different between the 2 groups.
Conclusion:
Treatment of displaced intraarticular calcaneal fractures with minimally invasive reduction and fixation using either cannulated screws or K-wires can achieve similar excellent functional and radiological outcomes, with high patient satisfaction. The use of K-wires has the advantage of reduced operative time than cannulated screws.
Levels Of Evidence:
Level III: Retrospective comparative study.