Positron Emission Tomography Imaging of Programmed Death 1 Expression in Cancer Patients Using 124I-Labeled

Shujing Wang1, Hua Zhu1, Jin Ding1

  • 1From the Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Nuclear Medicine, Peking University Cancer Hospital & Institute, Beijing.

Clinical Nuclear Medicine
|January 29, 2021
PubMed
Abstract

Insights

This study developed a novel radiotracer, 124I-labeled toripalimab (124I-JS001), for Positron Emission Tomography (PET) imaging. The tracer demonstrated safety and favorable biodistribution, showing potential for improved cancer patient selection.

Area of Science:

  • Nuclear Medicine
  • Oncology
  • Radiopharmaceutical Development

Background:

  • Anti-programmed cell death molecule-1 (PD-1)/PD-1 ligand therapy shows promise in oncology but suffers from low response rates.
  • Accurate biomarkers are needed to identify patients who will benefit from PD-1/PD-1 ligand therapy.
  • Positron Emission Tomography (PET) imaging offers a non-invasive method for evaluating drug distribution and target engagement.

Purpose of the Study:

  • To develop and clinically evaluate a novel PD-1 targeting radiotracer, 124I-labeled toripalimab (124I-JS001), for PET imaging.
  • To assess the biodistribution, safety, and dosimetry of 124I-JS001 in human subjects.
  • To explore the utility of 124I-JS001 PET/CT and PET/MR in visualizing tumor lesions.

Main Methods:

  • Eleven patients with melanoma or urologic cancer were enrolled.
  • 124I-JS001 PET/CT and PET/MR imaging were performed, with and without unlabeled JS001 co-injection.
  • 18F-FDG PET was conducted for comparison.

Main Results:

  • 124I-JS001 exhibited a favorable safety profile with acceptable dosimetry (0.236 mSv/MBq).
  • PET/CT showed high uptake in the spleen and liver, with varying uptake in tumor lesions (SUVmax 0.2–4.7).
  • Co-injection of unlabeled JS001 significantly reduced spleen uptake while increasing tumor uptake and tumor-to-background ratio.
  • PET/MR effectively detected tumor lesions and showed higher sensitivity for liver lesions compared to PET/CT.

Conclusions:

  • 124I-JS001 is a safe and well-tolerated radiotracer for clinical PET imaging.
  • The biodistribution of 124I-JS001 is favorable, with potential for improved tumor visualization when co-administered with unlabeled JS001.
  • PET/MR offers enhanced sensitivity for detecting liver metastases compared to PET/CT.