First Latin American and Caribbean interlaboratory comparison exercise for SSDLs on reference irradiation
H J Khoury1, V S M de Barros1, V K Asfora1
1Nuclear Energy Department, Federal University of Pernambuco, Av. Prof. Luiz Freire, 1000, Recife, PE 50740-545, Brazil.
Abstract:
A comparison exercise of Latin American and Caribbean Secondary Standards Dosimetry Laboratories (SSDLs) was jointly organized by the International Atomic Energy Agency (IAEA) and the Ionizing Radiation Metrology Laboratory at the Federal University of Pernambuco (LMRI-DEN/UFPE). This exercise was organized during an IAEA regional meeting on the review and update of calibration capabilities in Latin America, held in Recife, during the period from 23 to 27 April 2018 under the technical cooperation project ME-RLA 9085-170572. Fifteen participating SSDLs were required to irradiate optically stimulated personal dosimeters in terms of the personal dose equivalent Hp(10) in137Cs radiation quality. In addition, the IAEA Dosimetry Laboratory in Seibersdorf, Austria, and the National Physical Laboratory in Teddington, Middlesex, UK participated in this exercise as reference institutes. Each participant received 10 dosimeters that were hand-carried directly to the SSDL. Two nominal dose values of 2 mSv and 4 mSv were selected for this exercise. The participants irradiated the dosimeters using the setup and the procedures which are normally used in their standard laboratory for Hp(10) dosimeter irradiations. The dosimeters were evaluated as they were received by the coordinating laboratory, using a single BeOSL Reader. The results show that, except for one laboratory, the differences between the dosimeter reading and the assigned values were within 10%; this is consistent with the expanded uncertainty. The results indicate that most of the participant laboratories have a good capability to irradiate personal dosimeters in the quantity Hp(10).
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Biological Effects of Radiation