Related Experiment Video
Updated: Nov 19, 2025

Transdermal Measurement of Glomerular Filtration Rate in Mechanically Ventilated Piglets
Published on: September 13, 2022
Evaluation of the agreement between Brix refractometry and serum immunoglobulin concentration in neonatal piglets
A Schoos1, W De Spiegelaere2, A Cools3
1Department of Reproduction, Obstetrics and Herd Health, Unit of Porcine Health Management, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820 Merelbeke, Belgium.
Abstract:
Neonatal piglets lack immunoglobulins at birth. Sufficient colostrum intake (CI) and immunoglobulin absorption are essential for an appropriate passive transfer of immunity via the colostrum. Most methods to measure immunoglobulins in serum of piglets are labour-intensive, expensive or imprecise and not designed for on-farm use. The present diagnostic test study evaluated digital Brix refractometry to measure immunoglobulins in serum of neonatal piglets and to suggest thresholds for different serum immunoglobulin concentration. Additionally, agreements between Brix refractometry and optical refractometer (serum total protein, STP) and between Brix refractometry and ELISA (immunoglobulin G, IgG) were also investigated. Forty-five sows and 269 piglets from three different farms were enrolled in the study. Piglets were weighed at birth and 24 h later to calculate the CI. Serum was collected at 24 h after birth and analysed for STP, γ-globulins (electrophoresis), % Brix and IgG. In piglets, median (interquartile range, IQR) CI was 412 (196) g per piglet. Median (IQR) STP, γ-globulin and % Brix concentrations in piglet serum were 60 (11) g/L, 35 (10) g/L and 8 (2) %, respectively. Average (±SD) IgG concentration was 49 ± 23 g/L. Passing-Bablok regression revealed a strong concordance between % Brix and STP (Kendall's tau (Τ): 0.620, P < 0.0001, n = 267) and % Brix and γ-globulin concentration (Kendall's Τ: 0.575, P < 0.0001, n = 267). The agreement between the Brix refractometer and IgG concentration was poor (Kendall's Τ: 0.267, P < 0.0001, n = 269). Receiver operating characteristic curves were performed to evaluate test characteristics of Brix refractometry for three γ-globulin cut-off values, i.e. 10, 20 and 30 g/L. The % Brix cut-off values resulting in the optimal combination of sensitivity and specificity were 5.4 (100 and 98.5%), 7.0 (100 and 89.3%) and 7.9 (90.1 and 80.6%), respectively. In conclusion, digital Brix refractometry is a sufficiently fast and practical method to assess serum γ-globulin concentrations in neonatal piglets on-farm and to evaluate them by considering the thresholds found in this study. Further studies are needed to validate those thresholds regarding piglet's survival in the pre-weaning period.
More Related Videos
13:00Intranasal Immunization and Milk Collection in Studies of Maternal Immunization in New Zealand White Rabbits Oryctolagus cuniculus
Published on: July 31, 2021
08:58Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025