A short haptic diameter modified J-loop intraocular lens for improved capsular bag performance.

J A Davison1

  • 1Wolfe Clinic, P.C., Marshalltown, Iowa 50158.

Journal of Cataract and Refractive Surgery
|March 1, 1988
PubMed
Summary

This study introduces a modified J-loop intraocular lens (IOL) designed for improved capsular bag implantation and consistent centering. Clinical results show no complications in 314 implanted lenses over one year.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Overground endoscopy in 311 Thoroughbred racehorses: findings and correlation to resting laryngeal function.

Australian veterinary journal·2017
Same author

Delays to the definitive surgical management of pretibial lacerations in the elderly.

Journal of wound care·2006
Same author

Tissue reaction to titanium debris following Swanson arthroplasty in the hand: a report of two cases.

Journal of hand surgery (Edinburgh, Scotland)·2004
Same author

An aid to the dissection of small vessels in replantation.

Plastic and reconstructive surgery·2003
Same author

If the shoe fits.

British journal of plastic surgery·2003
Same author

Ontogeny, phylogeny and the origin of biological information.

Rivista di biologia·2001

Area of Science:

  • Ophthalmology
  • Biomaterials Science
  • Medical Device Engineering

Background:

  • Intraocular lens (IOL) technology is crucial for refractive error correction post-cataract surgery.
  • Ensuring optimal IOL centration and stability within the capsular bag is essential for visual outcomes.
  • Existing IOL designs may present challenges in specific anatomical conditions.

Purpose of the Study:

  • To present the laboratory and clinical characteristics of a novel modified J-loop intraocular lens (IOL).
  • To evaluate the ease of implantation and centration capabilities of the modified J-loop IOL in various capsular bag sizes.
  • To assess the safety and efficacy of the modified J-loop IOL through clinical implantation data.

Main Methods:

  • Laboratory evaluation of the modified J-loop IOL's physical characteristics, including optic material and haptic design.

Related Experiment Videos

  • Clinical implantation of 314 modified J-loop IOLs over a one-year period.
  • Post-operative assessment for IOL placement, decentration, and pupillary capture.
  • Main Results:

    • The modified J-loop IOL features a 6 mm polymethylmethacrylate optic and 12 mm haptic diameter with low compression resistance.
    • The haptic design facilitates easy implantation and consistent centration in small to moderate capsular bags.
    • No instances of asymmetric placement, optic decentration, or pupillary capture were observed in 314 implants.

    Conclusions:

    • The modified J-loop IOL demonstrates favorable laboratory and clinical characteristics for cataract surgery.
    • Its design promotes straightforward implantation and reliable centration, reducing potential complications.
    • The IOL shows a strong safety profile with excellent clinical performance in a large patient cohort.