Related Experiment Video
Updated: Nov 19, 2025

Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
A DESCRIPTION OF ARTERIAL BLOOD PRESSURE MEASUREMENT IN TWO SPECIES OF FLYING FOXES (PTEROPUS VAMPYRUS AND PTEROPUS
Bonnie J Gatson1, Vaidehi Paranjape2, James F X Wellehan3
1Department of Comparative, Diagnostic, and Population Medicine, University of Florida College of Veterinary Medicine, Gainesville, FL 32608, USA, bonniejh@ufl.edu.
Abstract:
Blood pressure assessment is valuable during management of chronic conditions with increased risk of developing hypertension and as a standard practice for anesthetic monitoring. Normal arterial blood pressure values have not been well described in megachiropteran species. Following anesthetic induction and maintenance with isoflurane in oxygen, arterial blood pressure was obtained from the posterior tibial artery of eight large flying foxes (Pteropus vampyrus) and six variable flying foxes (Pteropus hypomelanus), two with structural cardiac disease and four in good clinically health. Normal values reported as a median with interquartile range for systolic, diastolic, and mean (MAP) arterial pressures for P. vampyrus were 101 (94, 107), 69 (57, 80), and 86 (75, 93), respectively. Normal MAP for clinically healthy P. hypomelanus was 86 (67, 93). Placement of P. hypomelanus in a vertical head-down position did not alter blood pressure in clinically healthy bats, but significantly increased MAP in two bats with structural cardiac disease. Arterial catheterization of both the posterior tibial and median arteries in these species was easily performed without major complication.
More Related Videos
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure in the Leg
Preparation:

