Related Experiment Video
Updated: Nov 19, 2025

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
An iPPG-Based Device for Pervasive Monitoring of Multi-Dimensional Cardiovascular Hemodynamics
Jingjing Luo1,2, Junjie Zhen3, Peng Zhou2,3
1Institute of AI and Robotics, Academy for Engineering and Technology, Fudan University, Shanghai 200433, China.
Abstract:
Hemodynamic activities, as an essential measure of physiological and psychological characteristics, can be used for cardiovascular and cerebrovascular disease detection. Photoplethysmography imaging (iPPG) can be applied for such purposes with non-contact advances, however, most cardiovascular hemodynamics of iPPG systems are developed for laboratory research, which limits the application in pervasive healthcare. In this study, a video-based facial iPPG detecting equipment was devised to provide multi-dimensional spatiotemporal hemodynamic pulsations for applications with high portability and self-monitoring requirements. A series of algorithms have also been developed for physiological indices such as heart rate and breath rate extraction, facial region analysis, and visualization of hemodynamic pulsation distribution. Results showed that the new device can provide a reliable measurement of a rich range of cardiovascular hemodynamics. Combined with the advanced computing techniques, the new non-contact iPPG system provides a promising solution for user-friendly pervasive healthcare.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Holter Monitor: 24-Hour Monitoring
Measurement of Blood Pressure
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement

