Related Experiment Video
Updated: Nov 19, 2025

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
The influence of new immediate tissue level abutment on crestal bone stability of subcrestally placed implants: A
Tomas Linkevicius1,2, Rokas Linkevicius2, Evelina Gineviciute2
1Institute of Odontology, Vilnius University, Vilnius, Lithuania.
Background:
The relation between implant abutment disconnection (AD) and increased crestal bone loss is still debated.
Purpose:
To compare bone changes below implant-abutment junction of subcrestally placed implants between: (1) implant level restorations, that underwent four ADs and (2) implants with immediate tissue level abutment with no AD, 1 month (T2) and 1-year (T3) after final restoration delivery.
Materials And Methods:
Sixty-four patients received 64 bone level implants with platform-switching and conical connection in edentulous sites of posterior mandible and maxilla. All implants were placed 1.5 mm subcrestally and distributed among: (1) control group, that received a regular healing abutment and (2) test group with immediate tissue level (ITL) abutment, which was torqued to implants during surgery, transforming bone level implant to tissue level type. After 2-3 months of healing and a 1-month temporization, final zirconia-based screw-retained crowns were delivered to both groups. Crestal bone levels were calculated after final crown delivery (T2); after 1-year follow-up (T3) and compared using Mann-Whitney U test (p ≤ .05).
Results:
Early bone loss of the test and control groups was 0.14 ± 0.27 mm and 0.64 ± 0.64 mm, respectively; the 0.5 mm difference was statistically significant (p = .0001). Late bone loss was 0.06 ± 0.16 mm and 0.21 ± 0.56 mm for the test and control group, respectively; the 0.15 mm difference between the groups was no more statistically significant (p = .22). Both groups displayed bone gain, 0.08 and 0.43 mm, respectively, and the overall crestal bone loss was reduced.
Conclusions:
Immediate tissue level abutments can significantly reduce early bone loss when measured 1 month after final prosthesis delivery, however, after 1-year follow-up, difference between the groups was no more statistically significant.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
06:36Effects of Mechanical Methods Used in Peri-implantitis Treatment on Implant Surface Decontamination and Roughness
Published on: March 14, 2025