Diagnostic accuracy of automated occlusion detection in CT angiography using e-CTA
Fatih Seker1, Johannes Alex Rolf Pfaff1, Yahia Mokli2
1Department of Neuroradiology, Heidelberg University Hospital, Heidelberg, Germany.
Background And Aim:
The aim of this study was to assess the diagnostic accuracy of e-CTA (product name) (Brainomix) in the automatic detection of large vessel occlusions in anterior circulation stroke.
Methods:
Of 487 CT angiographies from patients with large vessel occlusions stroke, 327 were used to train the algorithm while the remaining cases together with 140 negative CT angiographies were used to validate its performance against ground truth. Of these 301 cases, 144 were randomly selected and used for an additional comparative analysis against 4 raters. Sensitivity, specificity, positive and negative predictive value (PPV and NPV), accuracy and level of agreement with ground truth (Cohen's Kappa) were determined and compared to the performance of a neuroradiologist, a radiology resident, and two neurology residents.
Results:
e-CTA had a sensitivity and specificity of 0.84 (0.77-0.89) and 0.96 (0.91-0.98) respectively for the detection of any large vessel occlusions on the correct side in the whole validation cohort. This performance was identical in the comparative analysis subgroup and was within the range of physicians at different levels of expertise: 0.86-0.97 and 0.91-1.00, respectively. For the detection of proximal occlusions, it was 0.92 (0.84-0.96) and 0.98 (0.94-1.00) for the whole cohort and 0.93 (0.80-0.98) and 1.00 (0.95-1.00) for the comparative analysis, respectively for e-CTA. The range was 0.8-0.97 for sensitivity and 0.97-1.00 for specificity for the four physicians.
Conclusions:
The performance of e-CTA in detecting any large vessel occlusions is comparable to less experienced physicians but is similar to experienced physicians for detecting proximal large vessel occlusions.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...