Related Experiment Video
Updated: Nov 19, 2025

Modified Drop Tower Impact Tests for American Football Helmets
Published on: February 19, 2017
Impact Performance Comparison of Advanced Snow Sport Helmets with Dedicated Rotation-Damping Systems
Gina DiGiacomo1, Stanley Tsai1, Michael Bottlang2,3
1Biomechanics Laboratory, Legacy Research Institute, Portland, OR, 97232, USA.
Abstract:
Rotational acceleration of the head is a principal cause of concussion and traumatic brain injury. Several rotation-damping systems for helmets have been introduced to better protect the brain from rotational forces. But these systems have not been evaluated in snow sport helmets. This study investigated two snow sport helmets with different rotation-damping systems, termed MIPS and WaveCel, in comparison to a standard snow sport helmet without a rotation-damping system. Impact performance was evaluated by vertical drops of a helmeted Hybrid III head and neck onto an oblique anvil. Six impact conditions were tested, comprising two impact speeds of 4.8 and 6.2 m/s, and three impact locations. Helmet performance was quantified in terms of the linear and rotational kinematics, and the predicted probability of concussion. Both rotation-damping systems significantly reduced rotational acceleration under all six impact conditions compared to the standard helmet, but their effect on linear acceleration was less consistent. The highest probability of concussion for the standard helmet was 89%, while helmets with MIPS and WaveCel systems exhibited a maximal probability of concussion of 67 and 7%, respectively. In conclusion, rotation-damping systems of advanced snow sport helmets can significantly reduce rotational head acceleration and the associated concussion risk.
More Related Videos
07:30A Test Bed to Examine Helmet Fit and Retention and Biomechanical Measures of Head and Neck Injury in Simulated Impact
Published on: September 21, 2017
07:02An Investigation of the Effects of Sports-related Concussion in Youth Using Functional Magnetic Resonance Imaging and the Head Impact Telemetry System
Published on: January 12, 2011
Related Concept Videos
Magnetic Damping
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
Types of Damping
Relative Motion Analysis using Rotating Axes - Acceleration
Time differentiation is...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Rotation of Asymmetric Top
The relationship between the angular momentum of any rigid body and its angular velocity, both of which are vectors, involves the moment of inertia. The moment of inertia is a scalar quantity only for spherically symmetric...