Implementing a Weaning Protocol for Noninvasive Respiratory Support in Neonates Decreases Overuse and Length of Stay
David N Matlock1, Sarah M Perez2, Heather A Borchert2
1University of Arkansas for Medical Sciences, Little Rock, Arkansas. DMatlock@uams.edu.
Background:
As part of efforts to decrease length of hospital stay, a protocol for weaning noninvasive respiratory support was implemented using quality improvement methodology. The objective of this study was to determine whether protocol implementation decreased the time to wean to no respiratory support by 24 h (30% reduction) over 3 months in preterm infants 30-34 weeks gestational age.
Methods:
A quality improvement project was conducted with the following outcome measures: primary outcome measured was hours to wean; secondary outcomes included duration of respiratory support, length of stay, and postmenstrual age at feeding milestones; and balance measures were duration of oxygen exposure and growth velocity.
Results:
Data from 89 subjects were included. Following implementation, decreases were seen in time to wean (40% reduction, P < .001), length of stay (25% reduction, P = .02), and growth velocity (21% reduction, P = .02).
Conclusions:
Implementing a weaning protocol decreases duration of support and length of stay in infants 30-34 weeks gestational age. Weaning respiratory support more quickly may decrease growth velocity.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Suctioning the Nasopharyngeal Airway
Equipment Required
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...