Related Experiment Video
Updated: Nov 19, 2025

Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
Comparative evaluation of T-Loop with different amount of pre-activation curvatures in lingual orthodontics- A finite
Pooja Girsa1, Ashish Kumar Singh1, Sridhar Kannan1
1Department of Orthodontics and Dentofacial Orthopaedics, Manav Rachna Dental College, Faridabad, Haryana, India.
Introduction:
Three-dimensional analysis of the moment, force and M/F ratio generated at the anterior and posterior region of the T-loop in five different groups of pre-activation curvatures using the finite element method.
Materials And Method:
In this study, the geometric model of maxilla was constructed using a CBCT scan. The bracket system simulated was of the STb lingual bracket system from Ormco (0.18slot) with specified tip and torque values of all maxillary teeth and the arch wire used was 0.016″x 0.016″ TMA (Ormco) for fabrication of T-loop with dimensions of 6 × 2 × 7 mm. There were five different models generated with pre-activation of: 20°,30°,40°,50° and 60° in T-loop. The software used for the post-processing of the model was ANSYS Workbench 19.2.
Result:
When the amount of pre-activation of T-loop increased there was an increase in the moment, force and M/F ratio in all the five groups in lingual biomechanics.
Conclusion:
Although, the M/F ratio depicts the type of movement that will take place is uncontrolled tipping in all the five pre-activation groups, clinically we should give pre-activation ranging from 30° to 60° in T-loop in lingual orthodontics.