Related Experiment Video
Updated: Nov 19, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Non-interventional monitoring of expiratory flow limitation during experimental mechanical ventilation
Giorgos Marinakis1, Michael Paraschos1, Maria Patrani1
1Dept of Critical Care Medicine, General Hospital of Athens, "Korgialenio - Benakio" Hellenic Red Cross, Athens, Greece.
Background:
Expiratory flow limitation (EFL) is common among patients in the intensive care unit under mechanical ventilation (MV) and may have significant clinical consequences. In the present study, we examine the possibility of non-interventional detection of EFL during experimental MV.
Methods:
Eight artificially ventilated New Zealand rabbits were included in the experiments. EFL was induced during MV by application of negative expiratory pressure (-5, -8 and -10 hPa) and detected by the negative expiratory pressure technique. Airway pressure (P aw) and gas flow (V') were digitally recorded and processed off-line for the evaluation of respiratory mechanics. The method is based on the computation and monitoring of instantaneous respiratory resistance R rs(t). The resistive pressure (P aw,res(t)) is calculated by subtracting from P aw its elastic component and the end-expiratory pressure, as assessed by linear regression. Then, R rs(t) is computed as the instant ratio P aw,res(t)/V'(t).
Results:
Two completely different patterns of expiratory R rs(t) separate the cases with EFL from those without EFL. Small and random fluctuations are noticed when EFL is absent, whereas the onset of EFL is accompanied by an abrupt and continuous rise in R rs(t), towards the end of expiration. Thus, EFL is not only detected but may also be quantified from the volume still to be expired at the time EFL occurs.
Conclusion:
The proposed technique is a simple, accurate and non-interventional tool for EFL monitoring during MV.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...