Design and Comparative Performance of a Robust Lung Auscultation System for Noisy Clinical Settings
Abstract:
Chest auscultation is a widely used clinical tool for respiratory disease detection. The stethoscope has undergone a number of transformative enhancements since its invention, including the introduction of electronic systems in the last two decades. Nevertheless, stethoscopes remain riddled with a number of issues that limit their signal quality and diagnostic capability, rendering both traditional and electronic stethoscopes unusable in noisy or non-traditional environments (e.g., emergency rooms, rural clinics, ambulatory vehicles). This work outlines the design and validation of an advanced electronic stethoscope that dramatically reduces external noise contamination through hardware redesign and real-time, dynamic signal processing. The proposed system takes advantage of an acoustic sensor array, an external facing microphone, and on-board processing to perform adaptive noise suppression. The proposed system is objectively compared to six commercially-available acoustic and electronic devices in varying levels of simulated noisy clinical settings and quantified using two metrics that reflect perceptual audibility and statistical similarity, normalized covariance measure (NCM) and magnitude squared coherence (MSC). The analyses highlight the major limitations of current stethoscopes and the significant improvements the proposed system makes in challenging settings by minimizing both distortion of lung sounds and contamination by ambient noise.
Related Concept Videos
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...


