Related Experiment Video
Updated: Nov 18, 2025

Electromagnetic Navigation Transthoracic Nodule Localization for Minimally Invasive Thoracic Surgery
Published on: May 4, 2022
Electromagnetic navigation reduces radiation exposure for retrograde drilling in osteochondrosis dissecans of the
Oliver D Jungesblut1,2, Josephine Berger-Groch3, Michael Hoffmann4
1Department of Pediatric Orthopedics, Altonaer Children's Hospital, Bleickenallee 38, 22763, Hamburg, Germany.
Background:
Retrograde drilling in osteochondrosis dissecans (OCD) is a widely used surgical intervention. A radiation-free electromagnetic navigation system (ENS)-based method was compared with the standard freehand fluoroscopic (SFF) method regarding clinical applicability.
Methods:
We performed a clinical cohort study at a department of Orthopaedics in a Level 1 children's hospital with 40 patients (20 SFF and 20 ENS). Retrograde drilling of the talar dome was used in patients with unstable medial OCD (MRI stage 2 according to Hepple's revised classification; stage 2 according to the International Cartilage Repair Society). The outcome measurements were: (a) Intraoperative fluoroscopy exposure and length of surgery and (b) Postoperative serial follow-up MRIs every 6 months.
Results:
22 female and 18 male patients aged 13.8 ± 1.6 years (range: 11-17 years) were included. Using the ENS technique, length of surgery was significantly reduced to 20.2 ± 6.4 min compared to 36.1 ± 11.8 min (p < 0.01) for the SFF technique. The average x-ray radiation time for the SFF technique was 23.5 ± 13.5 sec and 1.9 ± 1.7 sec for the ENS technique (p < 0.01). Radiation exposure was significantly reduced from 44.6 ± 19.7 mSv (SFF technique) to 5.6 ± 2.8 mSv (ENS technique) (p < 0.01). Intraoperative perforation of cartilage occurred once in the SFF group. Correct placement of the drilling channel was verified in all patients on follow-up MRI after six months and a timely healing was seen after two years.
Conclusions:
The ENS method provides for a significant reduction in length of surgery and radiation exposure. ENS was without intraoperative cartilage perforation. The clinical and radiological follow-up parameters are comparable for SFF- and ENS-guided retrograde drilling.
Trial Registration:
WF - 085/20, 05/2020 "retrospectively registered" https://www.aerztekammer-hamburg.org/ethik_kommission.html .
More Related Videos
05:37Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
07:24Autologous Microfractured and Purified Adipose Tissue for Arthroscopic Management of Osteochondral Lesions of the Talus
Published on: January 23, 2018