Related Experiment Video
Updated: Nov 18, 2025

Puncture-Induced Iris Neovascularization as a Mouse Model of Rubeosis Iridis
Published on: March 8, 2018
Novel mechanism of decreased iris vasculature density after cosmetic iris implants
Jason A Goldsmith1, Prateek Agarwal2,3, Scott D Smith1
1Eye Institute, Cleveland Clinic, Abu dhabi, UAE.
Abstract:
A 25-year-old man presented with decreased vision in both eyes, approximately 4 years following bilateral bright ocular cosmetic iris implantation. On examination, he was found to have bilateral elevated intraocular pressures, anterior chamber cells and flare, chronic peripheral anterior synechiae and significantly reduced endothelial cell counts. Ultrasound biomicroscopy demonstrated compression of the peripheral iris, resulting in synechial angle closure in both eyes. Surgical removal of the implants was performed without additional complication. On removal, bilateral iris atrophy was evident with non-reacting pupils and permanent mydriasis. Optical coherence tomography angiography showed a reduction in iris vasculature density that is more pronounced in the area of the iris atrophic defects. This case suggests that cosmetic iris implants may compress iris vasculature, resulting in decreased iris perfusion resulting in atrophic mydriasis and iris defects. This is a potential novel mechanism for complications in eyes with cosmetic iris implants.
Related Concept Videos
Glaucoma: Overview
Angle Closure Glaucoma: Treatment