Related Experiment Video
Updated: Nov 18, 2025

08:43
A Fluorescence Fluctuation Spectroscopy Assay of Protein-Protein Interactions at Cell-Cell Contacts
Published on: December 1, 2018
11.7K
Confocal-based fluorescence fluctuation spectroscopy with a SPAD array detector
Eli Slenders1, Marco Castello1, Mauro Buttafava2
1Molecular Microscopy and Spectroscopy, Istituto Italiano di Tecnologia, Genoa, Italy.
Light, Science & Applications
|February 5, 2021
Summary
This study introduces a new detector array for confocal laser-scanning microscopy (CLSM) combined with fluorescence fluctuation spectroscopy (FFS). This innovation simplifies data analysis and enables advanced imaging techniques for studying biomolecular processes.
Area of Science:
- Biophysics
- Cell Biology
- Microscopy
Background:
- Confocal laser-scanning microscopy (CLSM) coupled with fluorescence fluctuation spectroscopy (FFS) is vital for analyzing rapid, sub-resolution biomolecular dynamics in live cells.
- Existing detector arrays for CLSM-based FFS require complex data corrections and limit integration with single-photon methods like fluorescence lifetime imaging.
Purpose of the Study:
- To overcome limitations of current detector arrays in CLSM-FFS systems.
- To introduce a novel single-photon-avalanche-diode (SPAD) array detector for enhanced CLSM-FFS analysis.
- To enable simultaneous spatial and temporal data acquisition for biomolecular studies.
Main Methods:
- Integration of a novel single-photon-avalanche-diode (SPAD) array detector into a CLSM system.
- Validation using multiple FFS techniques: spot-variation fluorescence correlation spectroscopy, pair-correlation function analysis, and image-derived mean squared displacement analysis.
- Demonstration of simultaneous acquisition of multiple samples within the CLSM detection volume.
Main Results:
- The novel SPAD array detector successfully overcomes previous limitations in CLSM-FFS.
- The system allows for simplified data correction and seamless integration with single-photon techniques.
- Validated FFS analyses confirm the detector's capability for precise biomolecular process studies.
Conclusions:
- The developed CLSM system with a SPAD array detector offers a powerful and versatile tool for studying fast, sub-resolution biomolecular processes.
- This architecture provides a unique combination of spatial and temporal information, making it ideal for advanced live-cell imaging.
- The proposed method is poised to become a preferred technique for CLSM-based FFS applications.
More Related Videos
Related Concept Videos
Confocal Fluorescence Microscopy
19.3K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
19.3K
Super-resolution Fluorescence Microscopy
11.9K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
11.9K
Atomic Fluorescence Spectroscopy
680
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
680

