Effect of offset-frequency step size and interpolation methods on chemical exchange saturation transfer MRI
Ayan Debnath1,2, Rakesh Kumar Gupta3, Ravinder Reddy2
1Center for Biomedical Engineering, Indian Institute of Technology Delhi, New Delhi, India.
Abstract:
Chemical exchange saturation transfer (CEST) MRI is a non-invasive molecular imaging technique with potential applications in pre-clinical and clinical studies. Applications of amide proton transfer-weighted (APT-w), glutamate-weighted (Glu-w) and creatine-weighted (Cr-w) CEST, among others, have been reported. In general, CEST data are acquired at multiple offset-frequencies. In reported studies, different offset-frequency step sizes and interpolation methods have been used during B0 inhomogeneity correction of data. The objective of the current study was to evaluate the effects of different step sizes and interpolation methods on CEST value computation. In the current study, simulation (Glu-w, Cr-w and APT-w) and experimental data from the brain were used. Experimental CEST data (Glu-w) were acquired from human volunteers at 7 T and brain tumor patients (APT-w) at 3 T. During B0 inhomogeneity correction, different interpolation methods (polynomial [degree-1, 2 and 3], cubic-Hermite, cubic-spline and smoothing-spline) were compared. CEST values were computed using asymmetry analysis. The effects of different step sizes and interpolation methods were evaluated using coefficient of variation (CV), normalized mean square error (nMSE) and coefficient of correlation parameters. Additionally, an optimum interpolation method for APT-w values was selected based upon fitting accuracy, T-test, receiver operating characteristic analysis, and its diagnostic performance in differentiating low-grade and high-grade tumors. CV and nMSE increase with an increase in step size irrespective of the interpolation method (except for cubic-Hermite and cubic-spline). The nMSE of Cr-w and Glu-w CEST values were least for polynomial (degree-2 and 3). The quality of Glu-w CEST maps became coarse with the increase in step size. There was a significant difference (P < .05) between low-grade and high-grade tumors using polynomial interpolation (degree-1, 2 and 3); however, linear interpolation outperforms other methods for APT-w data, providing the highest sensitivity and specificity. In conclusion, depending upon the saturation parameters and field strength, optimization of step size and interpolation should be carried out for different CEST metabolites/molecules. Glu-w, Cr-w and APT-w CEST data should be acquired with a step size of between 0.2 and 0.3 ppm. For B0 inhomogeneity correction, polynomial (degree-2) should be used for Glu-w and Cr-w CEST data at 7 T and linear interpolation should be used for APT-w data at 3 T for a limited frequency range.
More Related Videos
13:56The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
Published on: November 19, 2014
08:51Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Related Concept Videos
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
NMR Spectroscopy: Chemical Shift Overview
For instance, the proton...
NMR Spectrometers: Resolution and Error Correction
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Magnetic Resonance Imaging