Related Experiment Video
Updated: Nov 18, 2025

Optimization of Processing of Tiebangchui with Highland Barley Wine Based on the Box-Behnken Design Combined with the Entropy Method
Published on: May 19, 2023
In depth investigation of the retention behavior of structurally related β-blockers on RP-HPLC column: Quality by
Ahmed Faried Abdel Hakiem1, Ahmed K Hamdy2, Hassan Refat Hassan Ali3
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Kafrelsheikh University, Kafrelsheikh 33516, Egypt.
Abstract:
The persistent introduction of new β-blockers motivates the demand for optimizing RP-HPLC well-designed analytical procedures that could be applied to this structurally related and commonly prescribed pharmacological group in order to reduce time and chemicals consumption in quality control units. Betoxolol HCl (BEX) and Carvidolol (CAR) were selected as representative examples to conduct predictive studies based on two complementary approaches, Quality by design (QBD) and Quantitative structure property relationship (QSPR). In concern QBD, a Box-Behnken design was adopted at variable chromatographic parameters to achieve the most proper conditions that might be applied for efficient analysis of the majority of group members. On the other hand, the retention time was chosen as the target property in the QSPR study that was conducted onto seven β. blockers (the two investigated drugs in addition to five other β. blockers) to find the best correlated molecular descriptors to the retention behavior. Both external and internal validation studies have comparable quality with training levels. Hence a simple selection algorithm of conventional features provides robust confirmatory predictive QBD and QSPR models. Derringer's desirability function as as a multi-criteria approach was applied for getting the optimum chromatographic analysis conditions. Efficient analysis of BET and CAR was achieved at column temperatures of 26.00 and 27.50 °C, respectively using acetonitrile and phosphate buffer (pH 4.55) 70:30 v/v as a mobile phase with a flow rate of 1.00 mL/min, and UV detection at 220 nm. The method was validated in accordance to ICH guidelines, and had exhibited acceptable precision, accuracy, linearity, and robustness.
More Related Videos
07:29HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
Related Concept Videos
Structure-Activity Relationships and Drug Design
SAR studies the intricate relationship between a drug's chemical structure and biological activity. It focuses on understanding how modifications to a drug's structure can influence...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process
Biopharmaceutical Factors Influencing Drug Product Design: Overview