Related Experiment Video
Updated: Nov 18, 2025

Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Completeness of the operating room to intensive care unit handover: a matter of time?
Fabian Dusse1,2, Johanna Pütz1, Andreas Böhmer1
1Department of Anesthesiology and Intensive Care Medicine, University Witten/Herdecke, Medical Center Cologne-Merheim, Ostmerheimer Str. 200, 51109, Cologne, Germany.
Background:
Handovers of post-anesthesia patients to the intensive care unit (ICU) are often unstructured and performed under time pressure. Hence, they bear a high risk of poor communication, loss of information and potential patient harm. The aim of this study was to investigate the completeness of information transfer and the quantity of information loss during post anesthesia handovers of critical care patients.
Methods:
Using a self-developed checklist, including 55 peri-operative items, patient handovers from the operation room or post anesthesia care unit to the ICU staff were observed and documented in real time. Observations were analyzed for the amount of correct and completely transferred patient data in relation to the written documentation within the anesthesia record and the patient's chart.
Results:
During a ten-week study period, 97 handovers were included. The mean duration of a handover was 146 seconds, interruptions occurred in 34% of all cases. While some items were transferred frequently (basic patient characteristics [72%], surgical procedure [83%], intraoperative complications [93.8%]) others were commonly missed (underlying diseases [23%], long-term medication [6%]). The completeness of information transfer is associated with the handover's duration [B coefficient (95% CI): 0.118 (0.084-0.152), p<0.001] and increases significantly in handovers exceeding a duration of 2 minutes (24% ± 11.7 vs. 40% ± 18.04, p<0.001).
Conclusions:
Handover completeness is affected by time pressure, interruptions, and inappropriate surroundings, which increase the risk of information loss. To improve completeness and ensure patient safety, an adequate time span for handover, and the implementation of communication tools are required.
Related Concept Videos
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:
SBAR I: Understanding the Concept
Standardized methods of communication have been developed to ensure that information is...
Discharge Summary Forms
Here's a detailed look at the key components and guidelines for preparing a discharge summary:
Methods of Documentation II: POMR
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Hand hygiene