Application of combined model of stepwise regression analysis and artificial neural network in data calibration of miniature air quality detector
Related Experiment Video
Updated: Nov 18, 2025

Asthma Detection Research Based on Voice Signal Processing and Machine Learning
Published on: July 22, 2025
Bing Liu1, Qingbo Zhao2, Yueqiang Jin3
1Public Foundational Courses Department, Nanjing Vocational University of Industry Technology, Nanjing, 210023, China. Liub1@niit.edu.cn.
Abstract:
In this paper, six types of air pollutant concentrations are taken as the research object, and the data monitored by the micro air quality detector are calibrated by the national control point measurement data. We use correlation analysis to find out the main factors affecting air quality, and then build a stepwise regression model for six types of pollutants based on 8 months of data. Taking the stepwise regression fitting value and the data monitored by the miniature air quality detector as input variables, combined with the multilayer perceptron neural network, the SRA-MLP model was obtained to correct the pollutant data. We compared the stepwise regression model, the standard multilayer perceptron neural network and the SRA-MLP model by three indicators. Whether it is root mean square error, average absolute error or average relative error, SRA-MLP model is the best model. Using the SRA-MLP model to correct the data can increase the accuracy of the self-built point data by 42.5% to 86.5%. The SRA-MLP model has excellent prediction effects on both the training set and the test set, indicating that it has good generalization ability. This model plays a positive role in scientific arrangement and promotion of miniature air quality detectors. It can be applied not only to air quality monitoring, but also to the monitoring of other environmental indicators.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Related Concept Videos
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Mechanistic Models: Compartment Models in Individual and Population Analysis
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...