Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Simulation of the effects of negative thermal gradients on separation performance of gas chromatography
Jan Leppert1, Leonid M Blumberg2, Matthias Wüst1
1Institute of Nutritional and Food Sciences, University of Bonn, Friedrich-Hirzebruch-Allee 5, D-53115 Bonn, Germany.
Abstract:
The effect of a gradient of solute velocity on the chromatographic separation of closely spaced solutes is investigated by usage of a simulation. The concept of the ideal basic separation (IBS), introduced by Blumberg, is used to determine the theoretical limit of a separation without any natural or artificial gradients of features of the chromatographic medium. The IBS is the best achievable separation and can therefore be used as a baseline to which other separations can be compared to. An addition of a negative velocity gradient cannot improve the separation of closely spaced solutes. The velocity gradient is realized by adding a temperature gradient to a GC separation. The simulation confirms this theoretical limit for a range of differently strong retained solutes. In a second part controlled deviations from IBS are used to show, that a velocity gradient can be beneficial in realistic, non-IBS. The addition of a negative velocity gradient can improve e.g. the separation of broad injected solute zones or counteract a positive gradient of the mobile phase velocity caused by gas decompression along the GC column. However, the improved separation cannot exceed that of a corresponding ideal basic separation. The resolution of broadly injected solutes can be increased by up to 45% of the corresponding IBS resolution by adding a negative velocity gradient. A positive velocity gradient due to gas decompression reduces the separation by up to 6%. The added negative velocity gradient, realized by a linear temperature gradient, can compensate this resolution loss by up to 2%.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....