Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Usage considerations for headspace-gas chromatography-ion mobility spectrometry as a suitable technique for
Natividad Jurado-Campos1, Andrés Martín-Gómez1, David Saavedra1
1Department of Analytical Chemistry, University of Córdoba, Faculty of Sciences, International Agri-food Campus of Excellence (ceiA3), Marie Curie Annex Building, Campus de Rabanales, 14071 Córdoba, Spain.
Abstract:
The potential of headspace-gas chromatography-ion mobility spectrometry (HS-GC-IMS) to perform non-targeted qualitative analysis of complex samples has led to an unprecedented increase in its popularity in recent years. The operating principle of IMS makes quality control essential to ensure adequate results. Besides this, the suitability of GC-IMS is determined by multiple phenomena that take place before and during IMS detection. The present work discusses a novel GC-IMS quality control protocol for both beginners and experienced users. Likewise, it describes factors that must be taken into account in order to develop a robust GC-IMS qualitative analysis method and, if needed, to achieve the identification of VOCs present in real samples. The developed quality control protocol was successfully employed in our laboratory for the routine analysis of >500 real samples (olive oil and Iberian ham) for 6 months, thus it is recommended for the analysis of a great number of complex samples. Furthermore, the behaviour of the ions produced in the ionisation chamber and the possible reactions between them in GC-IMS qualitative analysis were assessed.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...