Related Experiment Video
Updated: Nov 18, 2025

A Machine Learning Approach to Design an Efficient Selective Screening of Mild Cognitive Impairment
Published on: January 11, 2020
Classification with a Deferral Option and Low-Trust Filtering for Automated Seizure Detection
Thijs Becker1, Kaat Vandecasteele2, Christos Chatzichristos2
1I-Biostat, Data Science Institute, Hasselt University, 3500 Hasselt, Belgium.
Abstract:
Wearable technology will become available and allow prolonged electroencephalography (EEG) monitoring in the home environment of patients with epilepsy. Neurologists analyse the EEG visually and annotate all seizures, which patients often under-report. Visual analysis of a 24-h EEG recording typically takes one to two hours. Reliable automated seizure detection algorithms will be crucial to reduce this analysis. We investigated such algorithms on a dataset of behind-the-ear EEG measurements. Our first aim was to develop a methodology where part of the data is deferred to a human expert, who performs perfectly, with the goal of obtaining an (almost) perfect detection sensitivity (DS). Prediction confidences are determined by temperature scaling of the classification model outputs and trust scores. A DS of approximately 90% (99%) can be achieved when deferring around 10% (40%) of the data. Perfect DS can be achieved when deferring 50% of the data. Our second contribution demonstrates that a common modelling strategy, where predictions from several short EEG segments are combined to obtain a final prediction, can be improved by filtering out untrustworthy segments with low trust scores. The false detection rate shows a relative decrease between 21% and 43%, and the DS shows a small increase or decrease.
Related Concept Videos
Seizures: Classification
Seizures are typically classified into two main categories: focal and generalized seizures.
Focal Seizures
Focal seizures originate from specific regions of the brain. These seizures are further sub-classified into two types:
Classification of Signals
A continuous-time signal holds a value at every instant in time, representing information seamlessly. In contrast, a discrete-time signal holds values only at specific moments, often denoted as x(n), where...
Force Classification
Contact and non-contact forces are two of the most widely used categories of forces. As the name suggests, contact forces require physical contact between two objects to act upon each other. Examples of contact forces include frictional,...
Drug Classes and Categories