Related Experiment Video
Updated: Nov 18, 2025

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
A comparative study of transradial versus transfemoral approach for flow diversion
Joshua H Weinberg1, Ahmad Sweid1, Batoul Hammoud2
1Department of Neurological Surgery, Thomas Jefferson University Hospital, Philadelphia, PA, USA.
Purpose:
Data in neurointerventional literature is extremely limited regarding the safety and efficacy of flow diversion using transradial access (TRA). We aim to demonstrate the safety and efficacy of intracranial aneurysm treatment with the Pipeline Embolization Device (PED) using TRA compared to transfemoral access (TFA).
Methods:
We conducted a retrospective analysis of a prospectively maintained database and identified 79 consecutive patients who underwent neuroendovascular embolization for cerebral aneurysms using the PED from April 2018 through October 2019. Patients were divided into 2 groups: TRA (32 patients) and TFA (47 patients). A comparative analysis was performed between the two groups.
Results:
There was no significant difference in postoperative intracranial hemorrhage (p>.99), symptomatic ischemic stroke (p=.512), access site complications (p=.268), or other complications (p=.512). However, there was a significant increase in overall complications (14.9% vs. 0.0%, p=.038) and procedure duration (71.4 min ± 31.2 vs. 58.5 ± 20.3, p=.018) in the TFA group. There was no significant difference in complete occlusion at latest follow-up (19/25, 76.0% vs. 35/40, 87.5%; p=.311), 6-month follow-up (17/23, 73.9% vs. 33/38, 86.8%; p=.303), or 12-month follow-up (8/8, 100.0% vs. 5/6, 83.3%; p=.429). There was also no significant difference in rate of retreatment (p>.99), morbidity (p=.512), mortality (p>.99), latest follow-up (p=.985), or loss of follow-up (p=.298).
Conclusions:
The feasibility and efficacy of flow diversion with the PED via TRA for the treatment of intracranial aneurysms is comparable to TFA. Widespread adoption of this approach may be facilitated by improvements in device navigation and manipulation via radial-specific engineering.