Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Concept proposal for a six-tier integrated dual tracer PET-CT (68Ga-PSMA and FDG) image scoring system ('Pro-PET'
Aadil Adnan1,2, Sandip Basu1,2
1Radiation Medicine Centre, Bhabha Atomic Research Centre, Tata Memorial Centre Annexe, Jerbai Wadia Road, Parel.
Objectives:
To develop and examine a scoring system in metastatic castration-resistant prostate carcinoma (mCRPC) that integrates findings of both 68Ga-prostate-specific membrane antigen (PSMA) and flurodeoxyglucose (FDG) PET-CT imaging in a single combined parameter and referred to as the 'Pro-PET' score.
Methods:
A six-tier integrated dual tracer PET-CT (68Ga-PSMA and FDG) Image Scoring System ('Pro-PET' score) was conceptualized, based on the findings of both 68Ga-PSMA-11 and FDG PET-CT in patients of mCRPC. This proposed integrated scoring was examined in a retrospective analytical study assessing mCRPC patients (n = 47) referred for 177Lu-PSMA-617 peptide receptor radioligand therapy (PRLT) and had both FDG and 68Ga-PSMA PET-CT undertaken within 15 days of each other without any interim treatment intervention. The 'Pro-PET' score grades and subgrades were assigned and compared with clinical data, such as histopathology, Gleason score, serum prostate-specific antigen (PSA), treatment response (symptomatic, biochemical, metabolic and anatomical) and survival [overall survival (OS) and progression-free survival (PFS)].
Results:
The Pro-PET score significantly correlated with symptomatic (P = 0.05), biochemical (P = 0.05), metabolic (P = 0.001) and anatomical (P = 0.012) responses, PFS (P = 0.03) and OS (P = 0.027). On multivariate analysis, histopathology, Gleason score and PSA as individual parameters were not significantly associated with OS and PFS, whereas the Pro-PET score was found to have a significant association (P = 0.001 for PFS and 0.011 for OS).
Conclusion:
The 'Pro-PET' scoring system integrating dual tracer PET-CT imaging findings in a single parameter appeared as a potentially promising prognostic marker that has the potential to enhance the objectivity and scientific basis of prostate carcinoma theranostics and prognostication.
More Related Videos
07:45Author Spotlight: Standardizing Mouse In Vivo PET Imaging with Body Conforming Molds and Automated Analysis
Published on: October 25, 2024
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET