Related Experiment Video
Updated: Jun 22, 2026

Bead Based Multiplex Assay for Analysis of Tear Cytokine Profiles
Published on: October 13, 2017
An Emerging Method to Assess Tear Film Spread and Dynamics as Possible Tear Film Homeostasis Markers
José Vicente García-Marqués1, Cristian Talens-Estarelles1, Noelia Martínez-Albert1
1Department of Optics and Optometry and Vision Sciences, University of Valencia, Valencia, Spain.
Abstract:
Purpose: This study aims to assess the performance of an analysis method to measure in vivo the movement speed of tear film particles post-blink as a measure of tear film spreading.Materials and methods: Ocular surface parameters and the recording of tear film particles' spreading post-blink were assessed in eighty-one healthy volunteers (43.7 ± 27.0 years) using Keratograph 5 M. The developed software automatically decomposed the video into frames to manually track particles' position for 1.75 seconds after a blink. The following tear film-dynamic metrics were automatically calculated: mean, median, maximum, and minimum particles' speed at different times after blinking and time for particle speed to decrease to <1.20 mm/second. Repeatability of each tear film-dynamic metric and its correlations with ocular surface signs and symptoms were analyzed. Binomial logistic regression was performed to assess the predictability of new metrics to ocular parameters.Results: Repeatability tended to be lower just after blinking (variability of 12.24%), whereas the metrics from 0.5 s onwards had acceptable repeatability (variability below 10%). Tear film-dynamic metrics correlated positively with Non-Invasive Break-Up Time (NIKBUT) while negatively with meibomian gland drop-out. Binomial logistic regression analysis revealed that tear film-dynamic metrics were able to predict NIKBUT. Nevertheless, no statistically significant association was found with gland drop-out. This means that higher particle speed is related to larger NIKBUT. The metric "time for particle speed to decrease to <1.20 mm/second" can be considered the best metric to assess the quality of the tear film, since it was more strongly correlated with NIKBUT (r = 0.42, p = .004), it was more strongly associated in the binomial logistic regression analysis with NIKBUT and showed good repeatability (variability = 5.49%).Conclusions: Tear film-dynamic metrics are emerging homeostasis parameters for assessing indirectly the tear film quality in natural conditions with acceptable repeatability.
More Related Videos
06:29Effect of Artificial Tear Formulations on the Metabolic Activity of Human Corneal Epithelial Cells after Exposure to Desiccation
Published on: May 2, 2020
09:04Author Spotlight: Isolating Biomolecules from Mouse Tears — A Methodology for Molecular Analysis and Biomarker Research
Published on: July 19, 2024