Related Experiment Video
Updated: Nov 18, 2025

Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry UPLC-HRMS
Published on: May 20, 2013
Comprehensive UHPLC-HR-MSE screening workflow optimized for use in routine laboratory medicine: Four workflows in one
Marie Mardal1, Ole-Martin Fuskevåg1, Petur Weihe Dalsgaard2
1Department of Laboratory Medicine, University Hospital of Northern Norway, Tromsø, Norway.
Abstract:
A comprehensive HR-MS screening can be used to identify thousands of drugs from a single analysis, which makes it a valuable tool for broad-scope component-resolved toxicological analysis. However, it is common practice in clinical toxicology to perform restricted data analysis to avoid examining and/or reporting data not requested for examination. In this study, a HR-MS screening workflow was developed to allow a comprehensive toxicological evaluation, but also restricted and levelled data analysis to fit in a clinical setting. Following precipitation and reconstitution, samples were injected on an UHPLC-HR-MS and data were analyzed with the data processing software UNIFI. Analytical validation of 38 selected drugs of abuse (DoA), included determination of matrix effect, recovery, process efficiency, and limit of identification (LOI). The method was tested on 49 authentic samples and matrix-matched ranges of calibrators for 95 drugs. The LOI ranged from 0.3 to 1426.7 ng mL-1 for most analytes which was within expected concentration range for authentic samples with THC-COOH (>1722.0 ng mL-1) and morphine (1426.7 ng mL-1) as notable exceptions. Four individual screening workflows were developed: 1) a targeted workflow to serve as orthogonal identification of the 38 selected DOAs from another in-house method, 2) a general toxicology workflow, 3) an extended toxicology workflow including new psychoactive substances (NPS), and 4) a workflow for NPS based on the online HighResNPS library. Our study presents a comprehensive LC-HR-MS toxicology screening method optimized for laboratory medicine. The workflow allows for levelled data reviewing when requested without compromising the ability to perform full toxicological analyses.
More Related Videos
07:34Large Scale Non-targeted Metabolomic Profiling of Serum by Ultra Performance Liquid Chromatography-Mass Spectrometry UPLC-MS
Published on: March 14, 2013
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019