Related Experiment Video
Updated: Nov 18, 2025

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Feasibility of single-shot compressed sensing cine imaging for analysis of left ventricular function and strain in
1Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, No 300, Guangzhou Road, Nanjing, Jiangsu, 210029, China.
Aim:
To compare single-shot compressed sensing (CS) cine imaging with conventional segmented cine imaging for reliable quantification of left ventricular (LV) volume and strain assessment during cardiac magnetic resonance imaging (CMRI).
Materials And Methods:
Thirty-seven participants underwent both single-shot CS and conventional segmented cines that covered the entire LV. LV volumetric and strain values were obtained. LV volumes, global strain, the standard deviation of time to peak strain (SD-TPS) in the radial, longitudinal, and circumferential directions were compared using the Student's t-test and intraclass correlation coefficient (ICC). Interobserver and intra-observer variabilities of the LV strain values for the two cines method were determined using ICC.
Results:
Single-shot CS cine-derived LV volumes and myocardial mass measurements correlated strongly with segmented cines (ICC >0.798) and minor systematic end-systolic volume overestimations resulting in ejection fraction underestimations. Single-shot CS cine-derived global strain and SD-TPS were poorly to moderately correlated with segmented cines (ICC from 0.045-0.706). All global strain values derived from single-shot CS cines were underestimated compared with segmented cine-derived values; however, no significant differences in radial and longitudinal SD-TPS between the two cines were found. Among the patient-related factors, heart rate was a strong predictive factor of global longitudinal strain underestimations (p=0.039) in the CS cines. Inter- and intra-observer LV strain variabilities derived from CS and segmented cines were good to excellent.
Conclusion:
Single-shot CS cine CMRI is feasible for the quantitative assessment of LV function. Currently, strain values derived from the two techniques are not interchangeable.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

