The Iris Thickness in a Healthy Saudi Population
Yasir H Ziaul1, Alka Mahale1, Sejo Varghese1
1Research, King Khaled Eye Specialist Hospital, Riyadh, SAU.
Abstract:
Purpose Iris thickness (IT), a known risk factor for angle closure glaucoma, has not been evaluated in the normal Saudi population. Methods Quantitative information on IT was evaluated in healthy Saudi eyes using anterior segment optical coherence tomography (ASOCT). IT and iris volume was measured with the room 'light on' (LON) and 'light off' (LOFF) using Image J software. IT in the nasal and temporal iris was measured at 500 µm (IT500) and 750 µm (IT750) from the scleral spur (SS). Differences in IT measurements by age, gender and type of refractive error were evaluated. Results We included 100 eyes of 50 healthy adult Saudis without ocular disease other than refractive errors. The mean age of 56 males and 44 females in the study group was 41.7 ± 14.5 years. The refractive status was as follows: emmetropia (35 eyes), mild/moderate myopia (33 eyes), high myopia (17 eyes) and hyperopia (15 eyes). The IT750 with LON was significantly more than IT500 both nasally (P = 0.03) and temporally (P < 0.001). The difference in IT750 and IT500 with LOFF was significantly more nasally (P = 0.03), temporally (P = 0.02), and with LON nasally (P = 0.005). IT was thicker in males when compared to females and variation of IT by refractive error was significant but not by age. The mean pupil diameter and anterior chamber depth decreased with age (P < 0.001). Anterior chamber width was not affected by age or illumination. Conclusion The baseline iris thickness in the Saudi eyes could be used to compare iris thickness in eyes with angle closure glaucoma among the Arab population.
Related Concept Videos
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...


