Integrated dual lag screws versus single lag screw cephalomedullary nail constructs: a meta-analysis and systematic
James R Onggo1, Mithun Nambiar1, Jason D Onggo1
1Department of Orthopaedic Surgery, Maroondah Hospital, Victoria, Australia.
Background/Aim:
This study aims to determine the safety and efficacy of integrated dual lag screw (IDL) cephalomedullary nails (CMN) when compared with single lag screw (SL) constructs, in the internal fixation of intertrochanteric femoral fractures.
Methods:
The Smith & Nephew InterTan IDL was compared with SL CMN group consisting of the Stryker Gamma-3 (G3) and Synthes Proximal Femoral Nail Antirotation (PFNA) CMN. A multi-database search was performed according to PRISMA guidelines. Data from studies assessing the clinical and radiological outcomes, complications and perioperative parameters of InterTan versus G3 or PFNA CMN in patients with intertrochanteric femoral fractures were extracted and analysed.
Results:
15 studies were included in this meta-analysis, consisting of 2643 patients. InterTan was associated with lower complication rates in terms of all-cause revisions (OR 0.34; 95% CI, 0.22-0.51; p < 0.001), cut-outs (OR 0.30; 95% CI, 0.17-0.51; p < 0.001), medial or lateral screw migration (OR 0.19; 95% CI, 0.06-0.65; p = 0.008) as well as persistent hip and thigh pain (OR 0.65; 95% CI, 0.47-0.90; p = 0.008). In terms of perioperative parameters, InterTan is associated with longer operative times (MD 5.57 minutes; 95% CI, 0.37-10.78 minutes, p = 0.04) and fluoroscopy times (MD 38.89 seconds, 95% CI, 15.88-61.91 seconds; p < 0.001). There was no statistically significant difference in terms of clinical Harris Hip Score and radiological outcomes, non-union, haematoma, femoral fractures, varus collapse, length of stay and mean intraoperative blood loss between the 2 groups.
Conclusions:
Integrated dual lag screw cephalomedullary nails are associated with fewer revisions and complications. However, there is insufficient data to suggest that either nail construct is associated with better functional outcomes.
More Related Videos
09:07An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Wood Fasteners
Nails are the most common fasteners, consisting of sharp-pointed metal pins that are driven into wood using a hammer or a mechanical nail gun. They come in a variety of diameters, heads, and lengths. Nailing techniques include...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...