Robust Delay-Dependent Load Frequency Control of Wind Power System Based on a Novel Reconstructed Model
Related Experiment Video
Updated: Nov 18, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Abstract:
This article presents a novel reconstructed model for the delayed load frequency control (LFC) schemes considering wind power, which aims to improve the computational efficiency for PID controllers while retaining their dynamic performance. Via fully exploiting system states influenced by time delays directly, this novel reconstructed method is proposed with a controller isolated. Hence, when the PID controllers are unknown, the stability criterion based on this model can resolve controller gains with less time consumed. For given PID gains, this model can be employed to establish criteria for stability analysis, which can realize the tradeoff between the calculation accuracy and efficiency. The case study is first based on a two-area traditional LFC system to validate the merits of a novel reconstructed model, including accurately estimating the influence of time delay on system frequency stability with increased computational capability. Then, under traditional and deregulated environments, case studies are carried out on the two-area and three-area schemes, respectively. Through the novel reconstructed model, the efficiency of obtaining controller parameters is highly improved while their robustness against the random wind power, tie-line power changes, inertial reductions, and time delays remains almost unchanged.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
08:54Measurements of Waves in a Wind-wave Tank Under Steady and Time-varying Wind Forcing
Published on: February 13, 2018
Related Concept Videos
Turbine-Governor Control
Load-frequency control
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Generator Voltage Control
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Simplified Synchronous Machine Model
In this model, each generator is connected to a...