Related Experiment Video
Updated: Nov 17, 2025

Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Resting Dead Space Fraction as Related to Clinical Characteristics, Lung Function, and Gas Exchange in Male Patients
Ming-Lung Chuang1,2, Benjamin Yung-Thing Hsieh3, I-Feng Lin4
1Division of Pulmonary Medicine and Department of Internal Medicine, Chung Shan Medical University Hospital, Taichung, Taiwan, 40201, Republic of China.
Background:
Measures of forced expired volume in one second % predicted (FEV1%), residual volume to total lung capacity ratio (RV/TLC) and diffusing capacity for carbon monoxide measurements (DLCO) are the standard lung function test for evaluating patients with chronic obstructive pulmonary disease (COPD). The dead space fraction (VD/VT) has been shown to be a robust marker of gas exchange abnormality. However, the use of VD/VT has gradually become less common. As VD/VT measured at rest (VD/VTR) has been successfully used in non-COPD conditions, it was hypothesized that in COPD the VD/VTR was more sensitive than the standard lung function test in correlation with clinical characteristics and gas exchange. This study aimed to test the hypothesis and to identify the variables relevant to VD/VTR.
Methods:
A total of 46 male subjects with COPD were enrolled. Clinical characteristics included demographic data, oxygen-cost diagram (OCD), and image studies for pulmonary hypertension. The standard lung function was obtained. To calculate VD/VT, invasive arterial blood gas and pulmonary gas exchange (PGX) were measured. The variables relevant to VD/VTR were analyzed by multiple linear regression.
Results:
Compared to lung function, VD/VTR was more frequently and significantly related to smoking, carboxyhemoglobin level, pulmonary hypertension and PaCO2 (all p <0.05) whereas FEV1% was more related to lung function test, PaO2 and OCD score. VD/VTR and FEV1% were highly related to resting gas exchange but RV/TLC and DLCO% were not. Cigarette consumption, the equivalent for CO2 output, arterial oxyhemoglobin saturation, and the product of tidal volume and inspiratory duty cycle were identified as the parameters relevant to VD/VTR with a power of 0.72.
Conclusion:
Compared to lung function test, VD/VTR is more related to clinical characteristics and is a comprehensive marker of resting gas exchange. Further studies are warranted to provide a noninvasive measurement of VD/VTR.
Registration Number:
MOST 106-2314-B-040-025 and CSH-2019-C-30.
More Related Videos
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Respiratory Volumes and Capacities
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
External and Internal Respiration
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...