Conducting Respiratory Oscillometry in an Outpatient Setting
Published on: April 8, 2022
Measuring the mechanical input impedance of the respiratory system with breath-driven flow oscillations
Gregory S Roy1, Nirav Daphtary1, Olivia Johnson1
1Department of Medicine, Larner College of Medicine, University of Vermont, Burlington, Vermont.
Abstract:
In recent years, the mechanical input impedance of the respiratory system (Zrs) determined using the technique known as oscillometry has been gaining traction as a clinical diagnostic tool to complement conventional spirometry. Nevertheless, despite currently approved oscillometry devices being relatively compact and portable, they are still too heavy and bulky to be used in an ambulatory hands-free setting, mostly because of the mass of the motor and power supply. We therefore explored the possibility of using the subject's own respiratory musculature as the power source for creating flow oscillations at the mouth. We measured reference Zrs in 8 normal volunteers by having them breathe tidally into a piston-driven oscillator powered by an external motor. We fit the measured Zrs to the single-compartment model of the respiratory system characterized by the three parameters resistance (Rrs), elastance (Ers), and inertance (Irs). We then compared these parameter values to those obtained with two commercially available mucus-clearing devices that generate oscillations when expiratory flow drives a flapper valve. The estimates of Rrs agreed mostly within ±1 cmH2O·s·L-1, which is usefully accurate for most clinical needs. Ers and Irs agreed less well because the breath-driven oscillators provided data at essentially a single frequency close to the resonant frequency of the respiratory system. Nevertheless, we conclude that perturbing respiratory airflow and pressure with a breath-driven oscillator has the potential to provide measurements of Zrs, possibly serving as the basis for a lightweight ambulatory oscillometry system.NEW & NOTEWORTHY The technique of oscillometry for measuring the mechanical input impedance of the respiratory system is gaining traction as a clinical diagnostic tool, but the portability of existing commercially available devices is limited by the size and weight of oscillator motors and power supplies. We show that impedance can be measured by oscillations in mouth pressure and flow generated by mucus-clearing devices that are powered by the subject's own respiratory flow.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: