Method for Molecular Layer Deposition Using Gas Cluster Ion Beam Sputtering with Example Application In Situ
Matthias Lorenz1, Junting Zhang1, Alexander G Shard1
1National Physical Laboratory, Hampton Road, Teddington TW11 0LW, United Kingdom.
Abstract:
We introduce a technique for the directed transfer of molecules from an adjacent reservoir onto a sample surface inside the vacuum chamber of a ToF-SIMS instrument using gas cluster ion beam (GCIB) sputtering. An example application for in situ matrix-enhanced secondary ion mass spectrometry (ME SIMS) is provided. This protocol has attractive features since most modern SIMS instruments are equipped with a GCIB gun. No solvents are required that would delocalize analytes at the surface, and the transfer of matrix molecules can be interlaced with SIMS depth profiling and 3D imaging sputtering and analysis cycles, which is not possible with conventional ME SIMS strategies. The amount of molecular deposition can be finely tuned, which is important for such a surface sensitive technique as SIMS. To demonstrate the concept, we used 2,5-DHB as a matrix for the enhancement of three drug molecules embedded in a tissue homogenate. By automatic operation of sputter deposition and erosion (cleanup) cycles, depth profiling could be achieved with ME SIMS with good repeatability (<4% RSD). Furthermore, we explored several different matrix compounds, including α-CHCA and aqueous solutions of Brønsted acids (formic acid) and 3-nitrobenzonitrile, a volatile compound known to spontaneously produce ions. The latter two matrix compounds were applied at cryogenic measurement conditions, which extend the range of matrices applicable for ME SIMS. Enhancement ratios range from 2 to 13, depending on the analytes and matrix. The method works in principle, but enhancement ratios for the drug molecules are rather limited at this point. Further study and optimization is needed, and the technique introduced here provides a tool to perform systematic studies of matrix compounds and experimental conditions for their potential for signal enhancement in ME SIMS.
More Related Videos
07:103D Depth Profile Reconstruction of Segregated Impurities Using Secondary Ion Mass Spectrometry
Published on: April 29, 2020
09:38Dithranol as a Matrix for Matrix Assisted Laser Desorption/Ionization Imaging on a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
Published on: November 26, 2013
Related Concept Videos
Chemical Ionization (CI) Mass Spectrometry
Matrix-Assisted Laser Desorption Ionization (MALDI)
The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix material. The...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Mass Spectrometers
Mass Spectrometry: Overview