Related Experiment Video
Updated: Nov 17, 2025

Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
Time is bone - Quantitative comparison of decalcification solvents in human femur samples using
Joshua Gawlitza1, Jakob Steinhäuser2, Arno Bücker1
1Clinic of Diagnostic and Interventional Radiology, Saarland University Medical Center, Homburg, Saar, Germany.
Introduction:
Bone decalcification is a necessary preprocessing step in histological and anatomical studies. Several solutions for decalcification with different claimed times for full decalcification are commercially available. Current literature lacks direct, quantitative measurement of calcium hydrocyapatite degradation during decalcification to compare different solutions. Therefore, the aim of this study was to test the performance of three different decalcification solutions in human bone by direct measurement of calcium hydroxyapatite using dual-X-ray-absorptiometry (DEXA) and volumetric computed tomography (CT).
Methods:
Four femur slices were acquired from the proximal femur of a 76-year-old body donor. The slices were submerged in formaldehyde (control), EDTA, Osteosoft (Merck, Darmstadt, Germany) and "Rapid Bone Decalcifier" (RBD) (American MasterTech Scientific, Lodi, USA). Consecutive DEXA and CT scans were performed at 2 h, 4 h, 8 h, 11 h, 20 h, 44 h and 77 h after solutions were added. Besides the calcium hydroxyapatite concentration, the bone volume was measured each time.
Results:
Fastest decline in volume was seen in the RBD probe. Further, RBD was the only solution, being able to fully decalcify the bone slice after 77 h. Although a steady decline in volume and hydroxyapatite concentration was seen for EDTA and Osteosoft as well, both were not able to decalcify the slices.
Conclusion:
Overall, the purely qualititve acquired literature data on bone decalcifiers was verified by our quantitative data for human, cortical-rich bones. Hydrochloric-acid based solutions seem to be preferable in order to rapidly dissolve the calcium hydroxyapatite.