Related Experiment Video
Updated: Nov 17, 2025

Author Spotlight: Segmentation and VR for Advanced Neurovascular Interventions
Published on: April 5, 2024
The PROTAGORAS 2.0 Study to Identify Sizing and Planning Predictors for Optimal Outcomes in Abdominal Chimney
Stefano Fazzini1, Ombretta Martinelli2, Giovanni Torsello3
1Department of Vascular Surgery, St Franziskus Hospital, Münster, Germany; Unit of Vascular Surgery, Department of Surgery Paride Stefanini, Sapienza University of Rome, Rome, Italy.
Objective:
The aim was to identify predictors of adequate pre-operative sizing and planning for chimney endovascular aortic repair (ChEVAR) in order to reduce the incidence of persistent type Ia endoleaks (IaELs) without influencing chimney graft (CG) patency.
Methods:
Consecutive patients who underwent ChEVAR between January 2009 and December 2017 at a single centre were evaluated retrospectively. Included were patients treated with one device combination (Medtronic Endurant mated with Getinge Advanta V12/iCast) and placement of single or double CG. The freedom from IaEL related re-interventions and primary CG patency was estimated by measuring aortic stent graft oversizing (OS), total neck length (TNL), and a composite parameter (L-OS: TNL [mm] + OS [%]).
Results:
Seventy-three patients who underwent placement of 101 CGs (45 single, 28 double) met the inclusion criteria. The median radiological follow up was 25.5 (interquartile range [IQR] 12-48) months. Freedom from IaEL related re-intervention was achieved in 94.6% with a median OS of 38.5% (IQR 30%-44%, p = .004), TNL 19 mm (16-25 mm, p = .62), and L-OS 59 (51-65, p = .018). Primary CG patency was achieved in 95% of the cases with a median OS of 36% (29%-42%, p = .008), TNL 19 mm (15.5-26 mm, p = .91), and L-OS 57 (50-64, p = .005). By using the receiver operating characteristic curve, an optimal cut off to prevent IaEL related re-interventions was identified by an OS of 30% (p < .001; L-OS 55, p = .006) and to avoid CG stenosis/occlusions by OS 42% (p < .001; L-OS 65, p < .001). In multivariable analysis, aortic endograft OS was the only independent parameter preventive for IaEL related re-intervention (odds ratio, 0.78; 95% confidence interval, 0.61-0.99).
Conclusion:
With the Endurant-Advanta V12/iCast combination, an aortic stent graft OS of at least 30% (range 30%-42%) should be used to avoid type Ia endoleaks and likewise to ensure CG patency.
More Related Videos
09:40An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...