Related Experiment Video
Updated: Nov 17, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Process validation, current good manufacturing practice production, dosimetry, and toxicity studies of the carbonic
Ravindra A De Silva1, Michael A Gorin1,2, Ronnie C Mease1
1Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Abstract:
[111 In]In-XYIMSR-01 is a promising single-photon emission computed tomography (SPECT) imaging agent for identification of tumors that overexpress carbonic anhydrase IX. To translate [111 In]In-XYIMSR-01 to phase I trials, we performed animal toxicity and dosimetry studies, determined the maximum dose for human use, and completed the chemistry, manufacturing, and controls component of a standard regulatory application. The production process, quality control testing, stability studies, and specifications for sterile drug product release were based on United States Pharmacopeia chapters <823> and <825>, FDA 21 CFR Part 212. Toxicity was evaluated by using nonradioactive [113/115 In]In-XYIMSR-01 according to 21 CFR Part 58 guidelines. Organ Level INternal Dose Assessment/EXponential Modeling (OLINDA/EXM) was used to calculate the maximum single dose for human studies. Three process validation runs at starting radioactivities of ~800 MBq were completed with a minimum concentration of 407 MBq/ml and radiochemical purity of ≥99% at the end of synthesis. A single intravenous dose of 55 μg/ml of [113/115 In]In-XYIMSR-01 was well tolerated in male and female Sprague-Dawley rats. The calculated maximum single dose for human injection from dosimetry studies was 390.35 MBq of [111 In]In-XYIMSR-01. We have completed toxicity and dosimetry studies as well as validated a manufacturing process to test [111 In]In-XYIMSR-01 in a phase I clinical trial.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Clinical Trials: Overview