Performance of Prostate Imaging Reporting and Data System Version 2.1 for Diagnosis of Prostate Cancer: A Systematic
Kye Jin Park1, Sang Hyun Choi1, Mi-Hyun Kim1
1Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.
Background:
The Prostate Imaging Reporting and Data System (PI-RADS) was introduced in 2012 and updated to version 2.1 (v2.1) in early 2019 to improve diagnostic performance and interreader reliability.
Purpose:
To evaluate the diagnostic performance of PI-RADS v2.1 in comparison with v2.
Methods:
A systematic review and meta-analysis of the literature was performed using MEDLINE, EMBASE, and Cochrane databases to identify studies evaluating the diagnostic performance of PI-RADS v2.1 for diagnosing clinically significant prostate cancer (csPCa).
Study Type:
Systematic review and meta-analysis.
Subject:
One thousand two hundred forty-eight patients with 1406 lesions from 10 eligible articles.
Field Strength/Sequence:
Conventional MR sequences at 1.5 T and 3 T.
Assessment:
Two reviewers independently identified and reviewed the original articles reporting diagnostic performance of PI-RADS v2.1.
Statistical Tests:
Meta-analytic summary sensitivity and specificity were calculated using a bivariate random effects model. Meta-analytic sensitivity and specificity between PI-RADS v2 and v2.1 were compared.
Results:
The pooled sensitivity and specificity of PI-RADS v2.1 were 87% (95% confidence intervals, 82-91%) and 74% (63-82%), respectively. In five studies available for a head-to-head comparison between PI-RADS v2.1 and v2, there were no significant differences in either sensitivity (90% [86-94%] vs. 88% [83-93%], respectively) or specificity (76% [59-93%] vs. 61% [39-83%], respectively; P = 0.37). The sensitivity and specificity were 81% (73-87%) and 82% (68-91%), respectively, for a PI-RADS score cutoff of ≥4, and 94% (88-97%) and 56% (35-97%) for ≥3. Regarding the zonal location, the sensitivity and specificity for the transitional zone only were 90% (84-96%) and 76% (62-90%) respectively, whereas for the whole gland they were 85% (79-91%) and 71% (57-85%).
Data Conclusion:
PI-RADS v2.1 demonstrated good overall performance for the diagnosis of csPCa. PI-RADS v2.1 tended to show higher specificity than v2, but the difference lacked statistical significance.
Level Of Evidence:
3 TECHNICAL EFFICACY STAGE: 3.