Related Experiment Video
Updated: Nov 17, 2025

Characterization of a Pathogenic Escherichia coli Strain Derived from Oreochromis spp. Farms Using Whole-Genome Sequencing
Published on: December 23, 2022
Successful containment of two vancomycin-resistant Enterococcus faecium (VRE) outbreaks in a Dutch teaching hospital
K B Gast1, A J G van Oudheusden2, J L Murk1
1Microvida Laboratory of Medical Microbiology and Immunology, Elisabeth-TweeSteden Hospital, Tilburg, The Netherlands.
Background:
Vancomycin-resistant enterococci (VRE) may cause nosocomial outbreaks. This article describes all VRE carriers that were identified in 2018 at Elisabeth-Tweesteden Hospital, Tilburg, The Netherlands.
Aim:
To investigate the genetic relatedness of VRE isolates and the possibility of a common environmental reservoir using environmental sampling and whole-genome sequencing (WGS).
Methods:
Infection control measures consisted of contact isolation, contact surveys, point prevalence screening, environmental sampling, cleaning and disinfection. VRE isolates were sequenced using a MiSeq sequencer (Illumina, San Diego, CA, USA), and assembled using SPAdes v.3.10.1. A minimal spanning tree and a neighbour joining tree based on allelic diversity of core-genome multi-locus sequence typing and accessory genes were created using Ridom SeqSphere+ software (Ridom GmbH, Münster, Germany).
Findings:
Over a 1-year period, 19 VRE carriers were identified; of these, 17 were part of two outbreaks. Before environmental cleaning and disinfection, 55 (14%) environmental samples were VRE-positive. Fifty-one isolates (23 patient samples and 28 environmental samples) were available for WGS analysis. Forty-four isolates were assigned to ST117-vanB, five were assigned to ST17-vanB, and two were assigned to ST80-vanB. Isolates from Outbreak 1 (N=22) and Outbreak 2 (N=22) belonged to ST117-vanB; however, WGS showed a different cluster type with 257 allelic differences.
Conclusion:
WGS of two outbreak strains provided discriminatory information regarding genetic relatedness, and rejected the hypothesis of a common environmental reservoir. A high degree of environmental contamination was associated with higher VRE transmission. Quantification of environmental contamination may reflect the potential for VRE transmission and could therefore support the infection control measures.