Related Experiment Video
Updated: Nov 17, 2025

Microsurgical Creation of Giant Bifurcation Aneurysms in Rabbits for the Evaluation of Endovascular Devices
Published on: September 8, 2023
A Supplemental Technique for Preoperative Evaluation of Giant Intracranial Aneurysm
Hua-Wei Wang1, Chen Wu1, Zhe Xue1
1Chinese PLA General Hospital, Neurosurgery, Beijing, China.
Background:
Preoperative planning mainly relies on digital subtraction angiography (DSA) and computed tomography angiography. However, neither technique can reveal thrombi in giant intracranial aneurysms (GIAs). In this study, we aimed to reconstruct the circulating and noncirculating parts of GIAs with the time-of-flight (TOF) and motion-sensitized driven-equilibrium (MSDE) sequences with 3D Slicer to reveal an integrated presentation of GIAs, compare its accuracy, and validate the usefulness for preoperative planning.
Material And Methods:
Patients with GIAs who were treated with microsurgery in our department were included in this study. Both the TOF and MSDE sequence data for each patient were loaded into 3D Slicer for reconstruction and segmentation. The parameters measured by 3D Slicer were compared with those measured by DSA.
Results:
The mean diameter for all GIAs was 28.7 ± 1.5 mm (range, 25.9-31.9 mm). The mean diameter for all GIAs measured by DSA and 3D Slicer was 24.46 ± 5.25 and 28.66 ± 1.48 mm, respectively (t = 4.948, p < 0.01). When only the nonthrombotic GIAs were included, the mean diameter measured by DSA and 3D Slicer was 28.69 ± 2.03 and 28.97 ± 1.79 mm, respectively (t = 1.023, p = 0.323). The mean aneurysmal volume was 8,292.6 ± 1,175.1 mm3 and the mean thrombotic volume was 3,590.0 ± 1,003.7 mm3.
Conclusion:
The MSDE sequence brings diagnostic benefits as a comparison to other MRI sequences. Reconstruction of GIAs with 3D Slicer is a low-cost, dependable, and useful supplemental technique for surgical planning.
More Related Videos
11:58Minimally Invasive Thumb-sized Pterional Craniotomy for Surgical Clip Ligation of Unruptured Anterior Circulation Aneurysms
Published on: August 11, 2015
18:50Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment
Published on: September 25, 2009
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm III: Interprofessional Care
Aneurysm IV: Nursing Management