Management of a mechanical aortic valve during left ventricular assist device implantation in a previously replaced
Tamam Tulimat1, Bassam Osman1, Jean Beresian1
1American University of Beirut Medical Center, Beirut, Lebanon.
Abstract:
The use of left ventricular assist device (LVAD) in patients with mechanical aortic valves may result in thromboembolic events due to blood stasis around the valve and intermittent valve opening. Mechanical aortic valves encountered during LVAD implantation are managed by replacement with a tissue valve, or closure of the valve with a patch. Closure of the valve carries the risk of sudden death in cases of LVAD stoppage. Replacing the whole mechanical valve conduit is time consuming and carries a significant risk of bleeding and right ventricular (RV) failure. We describe an alternative technique of replacing a mechanical aortic valve by breaking its inner leaflets and sewing a tissue valve on top of the mechanical valve ring.